Chapter 1 › 1.4 › Slides
Slides · 1.4

Mounting

Read · 9 slides

1 / 9

Mounting

  • Prepare a surface, choose a mount and torque it
  • State its usable frequency limit and why

The Surface and the Hole

  • The base touching the surface all over: the contact is the stiffest spring in the mount
  • One guide: flat within 0.0003 in TIR, finished to 32 microinch; the sensor's own note governs
  • Spot-faced, deburred and cleaned; the tapped hole square to the surface
  • The stud never bottoms, in the hole or in the sensor's base

Grease and Torque

  • A thin film of silicone grease fills the gaps; a thick layer is a spring of its own
  • A torque wrench every time, to the sensor's datasheet value, and the torque written down
  • Under-torque lowers the resonance and loosens in the run; over-torque strips threads or breaks the stud

A Stud Mount, Right and Wrong

  • Flat surface, square hole deeper than the stud, thin grease, base seated, stud clear
  • Three faults: the stud bottomed, the hole at an angle, the base held off by a burr

a. The stud mount done right

sensormeasuring axistorqueper the datasheet,with a wrench,written downfixturebase seated all overthin film of grease (drawn thick)flat, spot-faced surfacestud clear of the end ofthe sensor's tapped holetapped hole square to the surfaceand deeper than the studstud clear of the bottomof the hole (the gap, bracketed)
b. Stud bottomedfixturesensorgapbottomedThe torque goes into the stud's endand the base sits loose on it: themounted resonance falls, and thewrench clicked.
c. Hole drilled at an anglefixturesensorgaptest axismeasuring axisThe base sits on one edge with a gapunder the rest: the mounted resonancefalls, and the sensor reads part of themotion across the test axis.
d. Base held off by a burrfixturesensorburrgapA burr at the hole's mouth holds thebase off the surface: it touches onlyat the burr, and the mountedresonance falls.

Grey cross-hatching is the fixture; blue dots are the grease film; a dashed red outline marks the fault. The geometry is exaggerated to show it.

Figure 1.4. A stud mount in section, the way it should be: a flat, spot-faced surface, a tapped hole square to it and deeper than the stud, a thin film of grease, the sensor's base seated all over, the stud clear of the bottom of the hole and of the sensor, and the torque written beside it. Three faults are drawn beside it, each with what it does to the mounted resonance: the stud bottomed, the hole drilled at an angle, the base held off by a burr.

Stud and Adhesive

  • The stud is the reference: highest resonance, holds at any level, the mount it was calibrated on
  • A thin, hard glue line of cyanoacrylate or stiff epoxy comes close; dental cement fills a curved surface
  • Every adhesive has a cure time and a temperature range
  • Removed with its solvent and patience, never struck or pried sideways

Cementing Studs, Magnets, Wax and the Hand Probe

  • Cementing stud: a pad glued once, the sensor screwed on at stud torque, removable and re-clockable
  • Magnet: steel only, extra mass and a softer joint; eased on, never let snap
  • Wax: about 40 C and about 10 g, a survey mount
  • Hand probe: spot checks below about 1,000 Hz

Six Mounts, One Sensor

  • The ranking travels from sensor to sensor; the frequencies do not
  • What travels is the fraction of mounted resonance

a. Six mounts on one sensor

Response on each mount over the stud-mounted response, against frequency as a fraction of the stud-mounted resonance. Marks where each curve leaves the flat line by 5 percent (circle), 10 percent (square) and 3 dB (triangle).

Six mounting methods as the ratio of the response to the stud-mounted response on log axes: the stud flat at one, the hand probe and the magnet rising to resonances far below the stud's, and falling away above them

b. The three highest mounts, close up

Adhesive, cementing stud and wax, on a linear scale near the top of the stud's usable range; hollow marks are the stud's own 5 percent, 10 percent and 3 dB points.

Adhesive, cementing stud and wax mounts rising away from the stud's flat line near the top of the range, with their marks

A model, not bench data: mounted resonances 1.00, 0.92, 0.85, 0.80, 0.25 and 0.07 of the stud's, Q 25 down to 4, all assumed. The ranking is the lesson; the frequencies belong to this model.

Figure 1.5. One sensor's response on six mounts, as a ratio to its stud-mounted response, across frequency as a fraction of its stud-mounted resonance: stud, adhesive, cementing stud, magnet, wax and hand probe. The 5 percent, 10 percent and 3 dB marks of Figure 1.3 are drawn on each mount's curve. The ranking holds for any sensor; the frequencies where each curve leaves the flat line belong to this sensor on this rig, and are read for another sensor from its own mounted resonance.

Blocks, Isolation and Where the Sensor Goes

  • A mounting block adds a joint and a mass: calibrate with it, count it in the limit
  • An isolated stud, insulating disc or insulated base breaks a ground loop, at a cost in resonance
  • The control sensor in a tapped hole on the fixture; response sensors on the article, usually glued

Decide

  • At full level, only a stud or a fully cured adhesive; cured cementing studs count as studs
  • Wax and magnets are survey mounts; the hand probe is a spot check
  • Every mount torqued with a wrench to the datasheet value, and the torque written down
  • Every channel's usable frequency limit written beside it in the channel table

Go to the quiz